location: Current position: Home >> Scientific Research >> Paper Publications

Fault Tolerance and Overmodulation Algorithm for Three Level Neutral Point Clamped Inverters

Hits:

Indexed by:会议论文

Date of Publication:2017-01-01

Included Journals:EI、CPCI-S、Scopus

Page Number:7358-7363

Key Words:Fault tolerance; eight-switch three-phase inverter; superposition principle; overmodulation

Abstract:It has been a hot issue and also a difficulty to study the fault tolerance of multilevel converters. The topology changes to eight-switch three-phase inverter (ESTPI) if one leg of three-level NPC inverter is failed. An optimal modulation algorithm of ESTPI is proposed in this paper. Due to the loss of one leg, the DC-link voltage utilization of ESTPI is reduced by half. Hence, an overmodulation algorithm based on superposition principle is proposed to improve DC-link voltage utilization, without increasing DC-link voltage. The proposed method is easier to implement compared with conventional overmodulation strategies for less computation. Theoretical proof and experimental results show that the proposed overmodulation algorithm is effective, and the DC-link voltage utilization can be increased maximally by 10.3%.

Pre One:Sensor Fault Diagnosis and System Reconfiguration Approach for an Electric Traction PWM Rectifier Based on Sliding Mode Observer

Next One:Overmodulation Strategy for Four-Switch Three-Phase Inverter Based on Virtual Voltage Vector