论文名称:Energy Impact of Air Pre-cooling on Screw Air Compressor 论文类型:会议论文 收录刊物:EI、CPCI-S 卷号:205 页面范围:937-944 关键字:screw air compressor; energy consumption; suction temperature; suction relative humidity 摘要:Air compressors are widely used in a variety of industries. The energy consumed by air compressors comprises a significant portion of the overall energy consumption in industrial plants. Both theoretical and experimental studies were conducted to investigate the impacts of air pre-cooling on the energy consumption of air compressor. Experiments were performed on a 11 kW screw air compressor. The paper presents the details of the modelling as well as the measured results. The results indicate that the energy consumption decreases by 0.65% for every 1 degrees C drop in suction temperature. The energy consumption decreases 0.243% for every 1% drop in suction relative humidity. Significant compressor energy consumption can be reduced by pre-treating or pre-cooling suction air. (c) 2017 The Authors. Published by Elsevier Ltd. 发表时间:2017-01-01