论文类型:会议论文
收录刊物:CPCI-S、EI
卷号:205
页面范围:937-944
关键字:screw air compressor; energy consumption; suction temperature; suction
relative humidity
摘要:Air compressors are widely used in a variety of industries. The energy consumed by air compressors comprises a significant portion of the overall energy consumption in industrial plants. Both theoretical and experimental studies were conducted to investigate the impacts of air pre-cooling on the energy consumption of air compressor. Experiments were performed on a 11 kW screw air compressor. The paper presents the details of the modelling as well as the measured results. The results indicate that the energy consumption decreases by 0.65% for every 1 degrees C drop in suction temperature. The energy consumption decreases 0.243% for every 1% drop in suction relative humidity. Significant compressor energy consumption can be reduced by pre-treating or pre-cooling suction air. (c) 2017 The Authors. Published by Elsevier Ltd.