梁若冰
开通时间:..
最后更新时间:..
点击次数:
论文类型:期刊论文
发表时间:2020-08-12
发表刊物:INTERNATIONAL JOURNAL OF PHOTOENERGY
收录刊物:SCIE
卷号:2020
ISSN号:1110-662X
摘要:This paper is aimed at improving the performance of a building-integrated photovoltaic thermal (BIPV/T) system driven by a refrigerant pump. The research is aimed at optimizing and upgrading the BIPV/T system to address the shortcomings of the original system by replacing roll-bond PV/T units with improved heat transfer features. The system's connecting form was redesigned using a liquid separator to solve the uneven distribution of the refrigerant on the PV/T facade. We proposed the variable frequency refrigerant pump that can be adjusted to suit the working condition. An experimental study was performed to analyze the electrical and thermal efficiency of the proposed system. The results show that the electrical efficiency of the BIPV/T system was 8% which is 14.3% higher than the traditional BIPV system, while in the test period, the BIPV/T system average COP was 3.4. The thermal and comprehensive efficiencies were 20% and 42%, respectively. Besides, the proposed system's average COP was 3.7 times greater than the original BIPV/T system.