Operational Characteristics of a Field-Breakdown Triggered Vacuum Switch

点击次数:

论文类型:期刊论文

发表时间:2009-01-01

发表刊物:14th International Symposium on Electromagnetic Launch Technology

收录刊物:SCIE、EI、CPCI-S

卷号:45

期号:1

页面范围:564-567

ISSN号:0018-9464

关键字:Field-breakdown TVS; lifetime; operational characteristics; trigger

摘要:Triggered vacuum switch (TVS) is one of the important switch apparatuses in the fields of high-pulsed power system. Its working lifetime is due to trigger failure of the trigger pin, so the parameters of trigger source become the key of lifetime dilatation. A sample of field-breakdown TVS coated with nothing is fabricated, which has much longer lifetime than the TVS coated with trigger materials, but more trouble in the trigger process. A trigger system and a LC test circuit are designed to find the operational characteristics of the TVS sample. The trigger system generates a negative pulse with peak value of 30 kV/500 A, the system delay and its scatter is controlled in 70-100 mu s, and the triggered rate of success reaches 96 %. Test results show that the sample has a wide working voltage range of 0.3-40 kV. The delay of its switching-on is stable in hundreds of nanoseconds, which will be reduced with the increase of main gap voltage. The arcing is steady in the conducting process, keeping arc voltage at 20 V approximately. The arc current drops to zero as current zero is approached, leading to a voltage remained in the capacitance.