齐民
开通时间:..
最后更新时间:..
点击次数:
论文类型:会议论文
发表时间:2010-06-26
收录刊物:EI、CPCI-S、Scopus
卷号:675-677
页面范围:333-336
关键字:Micro-arc oxidation; Arc ion plating; NiTi alloy; Titanium oxide; porous coating
摘要:NiTi alloys are widely used for bone implants due to their good mechanical properties. However, they can suffer certain disadvantages, such as leaching of toxic nickel ions and poor osteoinductive properties. A porous (Ca, P)-doped TiO2 /dense Ti double coatings on NiTi alloy with porous (Ca, P)-doped TiO2 coating as the top layer and a dense Ti coating as the interlayer should possess a very good combination of bioactivity and chemical stability. In this paper, the double coatings were formed by applying a duplex process of arc ion plating (AIP) and micro-arc oxidation (MAO). X-ray diffraction (XRD), scanning electron microscopy (SEM) and electron probe microanalysis (EPMA) have been used to investigate the microstructure and morphology of the coatings.