更多
论文成果
Automated detection and localization system of myocardial infarction in single-beat ECG using Dual-Q TQWT and wavelet packet tensor decomposition
点击次数:
论文类型: 期刊论文
发表时间: 2019-10-05
发表刊物: Computer methods and programs in biomedicine
收录刊物: PubMed、EI、SCIE
卷号: 184
页面范围: 105120
ISSN号: 1872-7565
关键字: Discrete wavelet packet transform (DWPT),Dual-Q tunable Q-factor wavelet transformation (Dual-Q TQWT),Electrocardiogram (ECG),Multilinear principal component analysis (MPCA),Myocardial infarction (MI)
摘要: It is challenging to conduct real-time identification of myocardial infarction (MI) due to artifact corruption and high dimensionality of multi-lead electrocardiogram (ECG). In the present study, we proposed an automated single-beat MI detection and localization system using dual-Q tunable Q-factor wavelet transformation (Dual-Q TQWT) denoising algorithm.After denoising and segmentation of ECG, a fourth-order wavelet tensor (leads × subbands × samples × beats) was constructed based on the discrete wavelet packet transform (DWPT), to represent the features considering the information of inter-beat, intra-beat, inter-frequency, and inter-lead. To reduce the tensor dimension and preserve the intrinsic information, the multilinear principal component analysis (MPCA) was employed. Afterward, 84 discriminate features were fed into a classifier of bootstrap-aggregated decision trees (Treebagger). A total of 78 healthy and 328 MI (6 types) records including 57557 beats were chosen from PTB diagnostic ECG database for evaluation.The validation results demonstrated that our proposed MI detection and localization system embedded with Dual-Q TQWT and wavelet packet tensor decomposition outperformed commonly used discrete wavelet transform (DWT), empirical mode decomposition (EMD) denoising methods and vector-based PCA method. With the Treebagger classifier, we obtained an accuracy of 99.98% in beat level and an accuracy of 97.46% in record level training/testing for MI detection. We also achieved an accuracy of 99.87% in beat level and an accuracy of 90.39% in record level for MI localization.Altogether, the automated system brings potential improvement in automated detection and localization of MI in clinical practice.Copyright © 2019. Published by Elsevier B.V.

张驰

副教授   硕士生导师

性别: 男

毕业院校:东北大学

学位: 博士

所在单位:生物医学工程学院

学科:生物医学工程. 信号与信息处理

电子邮箱:chizhang@dlut.edu.cn

辽ICP备05001357号 地址:中国·辽宁省大连市甘井子区凌工路2号 邮编:116024
版权所有:大连理工大学
访问量: 手机版 English 大连理工大学 登录

开通时间:..

最后更新时间:..