location: Current position: Home >> Scientific Research >> Paper Publications

Internal Defect Detection in Ferromagnetic Material Equipment Based on Low-Frequency Electromagnetic Technique in 20# Steel Plate

Hits:

Indexed by:期刊论文

Date of Publication:2018-08-15

Journal:IEEE SENSORS JOURNAL

Included Journals:SCIE

Volume:18

Issue:16

Page Number:6540-6546

ISSN No.:1530-437X

Key Words:Low frequency; saturation magnetization; internal defect detection

Abstract:A ferromagnetic material equipment internal defect detection system based on low-frequency (20-50 Hz) electromagnetic technique was proposed. Direct current magnetization was used to make the ferromagnetic material sample (20# steel for instance) be in a saturation magnetization state to decrease its permeability, which is beneficial for increasing the skin depth of the sample and strengthening the signal of the magnetic flux leakage. A low-frequency alternating current source was used to excite the spatial alternating electromagnetic field and a Hall sensor was used to collect the signal of the spatial magnetic field. Experimental results showed that the 6-mm buried depth internal defect with the sensitivity of 0.05 mm can be detected in the 12-mm thick 20# steel plate or pipeline, which is almost 1.5 times higher than that of the current similar sensors.

Pre One:Highly sensitive glucose detection using Au nanoparticles based fiber optic SPR sensor

Next One:Liquid surface tension and refractive index sensor based on a tilted fiber Bragg grating