Release Time:2019-03-09 Hits:
Indexed by: Journal Papers
Date of Publication: 2015-07-03
Journal: ENGINEERING OPTIMIZATION
Included Journals: Scopus、EI、SCIE
Volume: 47
Issue: 7
Page Number: 867-884
ISSN: 0305-215X
Key Words: sequential sampling designs; LBS; metamodel accuracy; space reduction
Abstract: In the field of engineering design and optimization, metamodels are widely used to replace expensive simulation models in order to reduce computing costs. To improve the accuracy of metamodels effectively and efficiently, sequential sampling designs have been developed. In this article, a sequential sampling design using the Monte Carlo method and space reduction strategy (MCSR) is implemented and discussed in detail. The space reduction strategy not only maintains good sampling properties but also improves the efficiency of the sampling process. Furthermore, a local boundary search (LBS) algorithm is proposed to efficiently improve the performance of MCSR, which is called LBS-MCSR. Comparative results with several sequential sampling approaches from low to high dimensions indicate that the space reduction strategy generates samples with better sampling properties (and thus better metamodel accuracy) in less computing time.