Hits:
Indexed by:会议论文
Date of Publication:2011-04-09
Included Journals:EI、CPCI-S、Scopus
Volume:194-196
Page Number:977-+
Key Words:Hydraulic Structure; Transient Temperature; Cooling Pipe; Creep; Program Development
Abstract:The transient temperature field and thermal creep surrounding concrete are analyzed with a three-dimensional FEM model that simulates the construction process of spiral case, based on program development of ABAQUS. The effect of hydration and cooling pipes on temperature is studied. The comparison of temperature difference in schemes is performed, and then the reasonable construction scheme has been defined. The distribution of thermal creep stress with construction is given. It is concluded that the control measures is effective to temperature crack prevention.