Hits:
Date of Publication:2015-01-01
Journal:岩石力学与工程学报
Volume:34
Issue:7
Page Number:1334-1344
ISSN No.:1000-6915
Abstract:The installation angle of feet-lock pipes has great influence on the
support effect in controlling the subsidence of steel arch. In order to
determine the reasonable installation angle,an analytical model of
feet-lock pipe and steel arch was established based on a brief analysis
of the working mechanism of feet-lock pipe. The theoretical correlation
between the installation angle of feet-lock pipe and the vertical
displacement of vault were derived using the theory of structural
analysis, elastic foundation beam, etc. Then an example of analysis was
presented in detail to determine the reasonable angle of installation of
feet-lock pipe and to explain the corresponding mechanism. Analysis
indicated that the reasonable installation angle of feet-lock pipe was
around 45°. More importantly, this was proved to be a general conclusion
which was consistent with large amounts of the experience from
construction site. Accordingly, the formulas derived in this paper were
proved to be correct.
Note:新增回溯数据