location: Current position: Home >> Scientific Research >> Paper Publications

红石水电站厂房的机组诱发振动及搞振加固研究

Hits:

Date of Publication:2002-01-01

Affiliation of Author(s):建设工程学部

Volume:0

Issue:1

Page Number:28-36

ISSN No.:1003-1243

Key Words:"powerhouse; resonance; reinforcement"

CN No.:11-2241

Abstract:In Honshi Hydropower Station there exists vibration of units and induced vibration of powerhouses and dams. It is concluded through the numerical and experiment research that the source of heavier vibration is due to the resonance between the units and the structures, which has caused the cracking of columns. Based on the research works, some proposals have been put forward to reinforce the powerhouse. After the measures are taken, the vibration frequency of the structure becomes much higher than the rotating speed of the units, so the resonance can be avoided. The amplitude of the structure vibration is also decreased remarkably.

Note:新增回溯数据