Hits:
Date of Publication:2022-10-09
Journal:机械工程材料
Volume:29
Issue:10
Page Number:14
ISSN No.:1000-3738
Abstract:The effect of parameters, electrical source power, purification time and
pipe radius on the purification efficiency of Al-24%Si hypereutectic
alloy was investigated in an alternating magnetic field. The
purification effect was better when the electrical source power was
higher, the purification time was longer and the piper radius of the
separator was thinner. The end effect occurred in the Al-melt of
work-coils end. The separated primary Si particles incorporated at the
separator pipe wall, and grew up into the Al-melt, which affected the
purification effect ; but it was constrained when the diameter of
separator pipe was 10 rnm and the power was 10 kW. The optimal effect
was achieved when the acting time was 30 s.
Note:新增回溯数据