location: Current position: Home >> Scientific Research >> Paper Publications

An electrochemiluminescence sensing for DNA glycosylase assay with enhanced host-guest recognition technique based on alpha-cyclodextrin functionalized gold/silica cell-shell nanoparticles

Hits:

Indexed by:期刊论文

Date of Publication:2015-03-01

Journal:ELECTROCHIMICA ACTA

Included Journals:SCIE、EI

Volume:157

Page Number:54-61

ISSN No.:0013-4686

Key Words:DNA glycosylase; electrochemiluminescence; alpha-cyclodextrin; gold/silica cell-shell nanoparticles

Abstract:An electrochemiluminescence (ECL) sensing for sensitive assaying of active DNA glycosylase was developed using the enhanced host-guest recognition technique. The alpha-cyclodextrinwas selected as the host molecule which captured the guest-labeled ECL probe to the surface of electrode by the host-guest recognition. The ECL probe can be protected from the digestion of exonuclease I (Exo I) and exonuclease III (Exo III) with the presence of the target enzyme human 8-oxoguanine DNA glycosylase 1 (hOGG 1), resulting in the ECL emission intensity was correlated with the quantity of hOGG 1. The alpha-cyclodextrin functionalized gold/silica (Au/SiO2) cell-shell nanoparticles was prepared to enhance the host-guest recognition sensitivity. Because of the increased recognition sites provided by alpha-cyclodextrin functionalized Au/SiO2 cell-shell nanoparticles, the nanoparticle-modified electrode displayed a high capacity for the guest ECL probe, and four fold enhancement of the ECL signals was achieved. The asprepared ECL sensing exhibits excellent analytical property for the detection of hOGG 1 in the linear range of 2-100 U mL(-1) with a detection limit of 0.225 U mL(-1) (S/N = 3). Interference tests show that the ECL intensity of the interferents human apurinic/apyrimidinic endonuclease (APE 1), T4 endonuclease V (T4 PDG) and endonuclease III (Endo III) is within 36.5 to 44.7% of that of hOGG 1. The ECL sensing exhibits long-term stability with a relative standard deviation (RSD) of 1.6% for 16 cycles of continuous potential scans, and the life time of the ECL sensing is up to 20 days. The obtained results in this study indicate that the proposed ECL sensing possesses high sensitivity, specificity and stability and provides a powerful tool for assaying hOGG 1 activity. (C) 2015 Elsevier Ltd. All rights reserved.

Pre One:Enhancement of anaerobic acidogenesis by integrating an electrochemical system into an acidogenic reactor: Effect of hydraulic retention times (HRT) and role of bacteria and acidophilic methanogenic Archaea

Next One:Enhanced Permeability, Selectivity, and Antifouling Ability of CNTs/Al2O3 Membrane under Electrochemical Assistance