location: Current position: Home >> Scientific Research >> Paper Publications

Liquid crystal filled surface plasmon resonance thermometer

Hits:

Indexed by:期刊论文

Date of Publication:2016-05-16

Journal:OPTICS EXPRESS

Included Journals:SCIE、EI

Volume:24

Issue:10

Page Number:10904-10911

ISSN No.:1094-4087

Abstract:A novel surface plasmon resonance (SPR) thermometer based on liquid crystal (LC) filled hollow fiber is demonstrated in this paper. A hollow fiber was internally coated with silver and then filled with LC. The SPR response to temperature was studied using modeling and verified experimentally. The results demonstrated that the refractive index of LC decreases with the increasing temperature and the variation can be detected by the resonance wavelength shift of the plasmon resonance. The temperature sensitivities were 4.72 nm/degrees C in the temperature range of 20 to 34.5 degrees C and 0.55 nm/degrees C in the temperature range of 36 to 50 degrees C, At the phase transition temperature between nematic and isotropic phases of the LC, the temperature sensitivity increased by one order of magnitude and a shift of more than 46 nm was observed with only a 1.5 degrees C temperature change. This sensor can be used for temperature monitoring and alarming, and can be extended for other physical parameter measurement. (C) 2016 Optical Society of America

Pre One:一种简单结构的全石英光纤EFPI高静压传感器

Next One:Multi-point fiber-optic refractive index sensor by using coreless fibers