location: Current position: Home >> Scientific Research >> Paper Publications

Corrosion-Induced Performance Degradation of Phosphorus-Containing Scale Inhibitors at Carbon Steel-Water Interface

Hits:

Indexed by:期刊论文

Date of Publication:2018-04-11

Journal:INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH

Included Journals:SCIE、EI

Volume:57

Issue:14

Page Number:5183-5189

ISSN No.:0888-5885

Abstract:Phosphorus-containing scale inhibitors have been widely used to mitigate CaCO3 scaling on the surface of metal device. In this work, the antiscale performances of two typical additives, sodium salts of hexametaphosphate (SHMP) and ethylenediaminetetramethylene phosphonate (EDTMPS), were evaluated on carbon steel through comparing scaling behavior under self-corrosion and cathodic polarization conditions, respectively. Results reveal that anodically released Fe2+ ions exert important influences on their antiscale behavior at carbon steel-water interface. During cathodic polarization processes, fewer or no Fe2+ ions are produced at the interface, and the two inhibitors effectively retard scale formation by their chelating role. However, once electrochemical corrosion occurs, more Fe2+ ions released from anode tend to diffuse toward cathodic regions, strongly interfering in their antiscale performances by preferentially replacing interfacial chelated Ca2+ ions. Then, these liberated Ca2+ ions are forced to react with cathodically formed CO3 ions, resulting in the scaling of CaCO3 at carbon steel-water interface.

Pre One:溴化橡胶循环冷却水系统结垢成因分析及防护对策

Next One:Origin of Aragonite Scale Deposition on Carbon Steel at Ambient Circumstances