![]() |
个人信息Personal Information
教授
博士生导师
硕士生导师
任职 : 精细化工全国重点实验室主任,教育部智能材料化工前沿科学中心执行主任,大连理工大学膜科学与技术研究开发中心主任
性别:女
毕业院校:中国科学院大连化物所
学位:博士
所在单位:化工学院
学科:化学工程. 膜科学与技术. 生物医学工程
联系方式:hgaohong@dlut.edu.cn
电子邮箱:hgaohong@dlut.edu.cn
Preparation and characteristics of crosslinked sulfonated poly (phthalazinone ether sulfone ketone) with poly(vinyl alcohol) for proton exchange membrane
点击次数:
论文类型:期刊论文
发表时间:2008-04-01
发表刊物:JOURNAL OF MEMBRANE SCIENCE
卷号:312
期号:1-2
页面范围:48-58
ISSN号:0376-7388
关键字:sulfonated poly(phthalazinone ether sulfone ketone); proton exchange membrane; crosslinking; polyelectrolytes; poly(vinyl alcohol)
摘要:In order to further overcome the trade-off between high conductivity and good mechanical property of proton exchange membrane (PEM), direct covalent crosslinking of sulfonated poly(phthalazinone ether sulfone ketone) (SPPESK) and poly(vinyl alcohol) (PVA) was prepared through post-heating process. Polymer PVA has attractive advantages to be a crosslinker with SPPESK, since the crosslinking of SPPESK with PVA requires relatively lower crosslinking temperature and has much higher stability in water, compared with small molecule crosslinker of glycol and glycerol. The crosslinking is confirmed by solubility change and analysis of ion exchange capacity (IEC) and sulfur content (C(S)) of uncrosslinked and crosslinked SPPESK with PVA (Un S-P and Cr S-P). Calculation of degree of crosslinking (DC) of sulfonic group shows that Most -SO(3)Hs of SPPESK are not involved in the crosslinking, which can maintain the ion exchange and proton transport function. ATR-FTIR spectra analysis manifests the PVA in Cr S-P are oxidized and dehydrated during the crosslinking process with SPPESK. Cr S-P membrane still has higher thermal stability, despite T(d) (252-273 degrees C) is less than that (306 degrees C) of pristine SPPESK. SEM images and XRD patterns show that the Cr S-P is a homogenous and amorphous material. Water uptake of Cr S-P membrane decreases with increasing PVA content, and Cr S-P membrane with lower PVA content (e.g. 15% and 20%) has high water uptake (111.1% and 98.0%) at 80 degrees C. All the swelling ratio values of Cr S-P (15-35% of PVA content) are at a lower level (<36%) even at 80 degrees C. Some Cr S-P membranes (with lower PVA content) have much higher conductivity than that of stable pristine SPPESK, e.g. conductivity of S-P 85/15 reaches 2.00 x 10(-2) S cm(-1) which is almost twice as that (1.03 x 10(-2) S cm(-1)) of SPPESK DS 81% membrane. All above properties of Cr S-P membrane (especially PVA content: 15-20%) indicate the kind of crosslinked sulfonated polymer with PVA is another alternative or prospective approach to prepare PEM. (C) 2008 Elsevier B.V. All rights reserved.