Indexed by:Journal Papers
Date of Publication:2019-08-15
Journal:暖通空调
Volume:49
Issue:8
Page Number:114-119,84
ISSN No.:1002-8501
Key Words:建筑节能;变风量空调;末端阀位;变静压模糊控制;调控规则
Abstract:分析了送风量调节中末端阀位与送风静压设定值之间的调控关系.基于作用模糊子集推理方法,提出了基于末端阀位调控规则的变静压模糊控制方法,该方法易于模块化封装,调试简单,便于实际工程应用.通过对比试验研究,验证了该方法的控制性能及节能效果.结果 表明:与传统的定静压法相比,采用变静压模糊控制方法在冬季和夏季工况下可分别减少14%和16%的送风机电耗;通过合理选择静压变化量的模糊基本论域,采用变静压模糊控制方法在冬季和夏季工况下分别可进一步减少33%和11%的送风机电耗.