Indexed by:Journal Papers
Date of Publication:2021-01-09
Journal:暖通空调
Volume:49
Issue:10
Page Number:97-104
ISSN No.:1002-8501
Key Words:变风量空调;独立新风系统;按需分配;新风控制;经济性分析
Abstract:介绍了不同传统变风量空调系统新风量控制方法的控制及节能效果,详细分析了变风量空调系统各个区域新风供给量及其需求量之间不匹配的问题.提出了基于独立新风系统的新风量保障方法.通过对比试验研究,分析了该新风量保障方法的经济性.结果 表明:基于独立新风系统的新风量保障方法可以很好地实现新风量的按需分配;在大连地区,空调系统使用年限在12 a以上时,采用独立新风系统可以达到很好的节能效果.